Melexis MLX90614ESF-BCC-000-TU single-point sensor scheme

Melexis MLX90614ESF-BCC-000-TU single-point sensor scheme

Author:    Time:2024-06-11    Browse:

Melexis MLX90614ESF-BCC-000-TU single-point sensor scheme


MELEXIS single point sensor 

(MLX90614ESF-BCC-000-TU sensor with Mailai core)

Module size diagram display:



Supply voltage: 3-5v 

Power supply current: 7mA

 Wiring:

 Red-------VCC

 Black--------GND

 Yellow--------RC (serial UART TTL-Rx / I2C--SCL) 

White--------TD (serial UART TTL-Tx / I2C--SCL) 

The module defaults to the serial port UART mode, which automatically outputs data. When the ps solder joint on the PCB is welded, it is I2C mode. 


1. Module internal register:

0x00 (reading and writing)  Device ID address  1~254; 0 is the broadcast address; the default is ID:0xA4, which is the same as the 8-bit IIC address, so the address must be a multiple of 2. 
0x01 (read and write)  Baud rate setting  0~7:2400,4800,9600,19200,38400,57600,115200,230400 
0x02 (read and write)  Update rate  0:1hz;1:2hz;2:5hz;3:10hz 
0x03 (read and write)  Output mode  0: Continuous output; 1: Query output 
0x04 (reading and writing)  Output format  0: hexadecimal; 1: character; 
0x05 (reading and writing)  Save settings  0x55: Save the current configuration; 0xAA: Restore factory settings 
0x06 (read and write)  TO_off temperature offset  0-255, default 100=0 offset, TO compensation = (TO_off-100)/10 
0x07 (read and write)  E emission rate  1~100 (corresponse to 0.01~1.00) 
0x08 (read)  TO (target temperature) 8 bits high  0~255
0x09 (read)  TO (target temperature) 8 bits lower  0~255
0x0a (read)  TA (ambient temperature) is 8 bit high  0~255
0x0b (read)  TA (ambient temperature) 8 bits lower  0~255
0x0c (read)  BO is 8 bits high  0~255 8 places higher body temperature conversion 
0x0d (read)  BO 8 bits lower  0~255 8 places lower body temperature conversion 
0x0e (read and write)  Chip model  0~3 
0x0f (read)  Firmware information  0~255


Serial port function (sending and receiving mode): 

Frame description:

2. Module support function code: 

3. Module response time 

5. Examples of modules: 

Write registers and configure registers. 

Configure the query mode output, and the main station sends the frame as: A4 06 03 01 AE (hexadecimal 0x01 = query mode output) 

The configuration baud rate is 115200, and the main send frame is: A4 06 01 06 B1 (hexadecimal 0x06 = 115200) 

The module response frame is: A4 06 01 06 B1 is the same as the main station sending frame, indicating that the configuration is successful. 


The configuration emission rate is 0.98, and the main station send frame is: A4 06 07 62 13 (hexadecimal 0x62 = decimal 98)


The module response frame is: A4 06 07 62 13 is the same as the main station sending frame, indicating that the configuration is successful.

Note: It takes more time to set the emissivity.  

Configure the temperature offset +1 degree, and the main station sends the frame as: A4 06 06 6E 1E (hexadecimal 0x6E = decimal 110)


The configuration temperature offset is -1 degree, and the main station sends the frame as: A4 06 06 5A 0A (hexadecimal 0x5A = decimal 90) 

If all configurations need to be saved by power-off, you need to send the power-off-saving instruction A4 06 05 55 04 

Read the register, the main station sends the frame as: A4 03 07 07 B5 

Module response frame: A4 03 07 07 62 0C EB 0C 3F 0E 20 87 

Frame resolution: 

Starting register 07 starts with the transmitt rate register, and the number of registers is 7, that is, 07 08 09 0A 0B 0C 0D The data output of these 7 registers in turn. Launch rate

Target temperature 

Ambient temperature 

Forehead temperature conversion body temperature 

Serial port data continuous output: 

A. Send reading data frame: Set the starting register and the number of registers. 

B. Set the output mode to continuous output mode, that is, write 1 to the 03 register. Serial port data query output: 

A. Set the output mode to query mode, that is, write 0 to the 03 register. 

    B. Send and read data frames: Set the starting register and the number of registers.

    Note: The output format of the data is determined by the reading data frame. The continuous/query mode is determined by the 03 register. Forehead temperature compensation: 

Changing the 06 register value can compensate for the frontal temperature. If the target measurement value is greater than the target actual value, the register value can be reduced, and vice versa, the register value can be increased.

IIC function: 

This function requires welding PS solder joints. The IIC address is 00 register value, and the default is A4. The IIC rate needs to be less than 400K. 

The number of single write registers of the module is 1. The writing sequence is as follows, which needs to be greater than 4us after sending the device address. 

The module supports multi-restor continuous reading. The reading sequence is as follows, and the delay needs to be 16us after sending the second device address.


6. Serial port upper computer test software





Contact Us:86-755 0755-84501787

Mailbox:jessie@szlitus.com

Headquarters Address:1808, Building A, Rongde International, Henggang Street, Longgang District, Shenzhen

Whatsapp

Whatsapp

WeChat

WeChat

Skype

Skype

Copyright © 2005-2023Shenzhen Lites Electronic Technology Co., Ltd All Rights Reserved Record number: Guangdong ICP backup2024178703-1 Background login

回到顶部图片